ean | 4015080032298 | ||
product height | 74 mm | ||
Product weight | .383 kg | ||
catalog notes | rated short-time withstand current (icw) for a time of 1 second | ||
10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
rated operational power at ac-3, 380/400 v, 50 hz | 11 kw | ||
mounting method | rear mounting | ||
Design | 15.168 | ||
number of switches | 1 | ||
degree of protection (front side) | ip65 | ||
short-circuit current rating (high fault) | 10 ka, sccr (ul/csa) 40 a, class j, max. fuse, sccr (ul/csa) |
||
rated operational current (ie) at dc-23a, 240 v | 5 a | ||
actuator type | door coupling rotary drive | ||
ambient operating temperature - max | 50 °c | ||
Features | version as emergency stop installation version as maintenance-/service switch version as main switch |
||
rated breaking capacity at 500 v (cos phi to iec 60947-3) | 240 a | ||
rated operational power star-delta at 380/400 v, 50 hz | 15 kw | ||
10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
operating frequency | 1200 operations/h | ||
number of contacts in series at dc-23a, 48 v | 2 | ||
terminal capacity | 2 x (0.75 - 4) mm², flexible with ferrules to din 46228 14 - 10 awg, solid or flexible with ferrule 1 x (1 - 6) mm², solid or stranded 2 x (1 - 6) mm², solid or stranded 1 x (0.75 - 4) mm², flexible with ferrules to din 46228 |
||
heat dissipation capacity pdiss | 0 w | ||
assigned motor power at 200/208 v, 60 hz, 1-phase | 3 hp | ||
switching angle | 90 ° | ||
Overvoltage category | iii | ||
actuator color | red | ||
rated operational current (ie) at dc-13, control switches l/r = 50 ms | 20 a | ||
rated operational power at ac-23a, 500 v, 50 hz | 15 kw | ||
switching power at 400 v | 15 kw | ||
functions | interlockable emergency switching off function |
||
rated operational power at ac-3, 690 v, 50 hz | 11 kw | ||
10.2.2 corrosion resistance | meets the product standard's requirements. | ||
10.2.7 inscriptions | meets the product standard's requirements. | ||
rated operational current (ie) star-delta at ac-3, 380/400 v | 32 a | ||
number of contacts in series at dc-21a, 240 v | 1 | ||
Shock resistance | 15 g, mechanical, according to iec/en 60068-2-27, half-sinusoidal shock 20 ms | ||
ambient operating temperature (enclosed) - min | -25 °c | ||
rated operational current (ie) at dc-21, 240 v | 1 a | ||
rated operational current (ie) at ac-23a, 500 v | 26.4 a | ||
rated operational power at ac-23a, 220/230 v, 50 hz | 7.5 kw | ||
10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
rated operational current (ie) at ac-21, 440 v | 32 a | ||
10.8 connections for external conductors | is the panel builder's responsibility. | ||
assigned motor power at 575/600 v, 60 hz, 3-phase | 10 hp | ||
rated operational current (ie) at ac-23a, 690 v | 17 a | ||
rated operational power at ac-3, 415 v, 50 hz | 11 kw | ||
device construction | built-in device fixed built-in technique | ||
static heat dissipation, non-current-dependent pvs | 0 w | ||
10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
Mounting position | as required | ||
10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
rated operational power star-delta at 220/230 v, 50 hz | 7.5 kw | ||
heat dissipation per pole, current-dependent pvid | 1.1 w | ||
switching capacity (auxiliary contacts, general use) | 10a, iu, (ul/csa) | ||
uninterrupted current | rated uninterrupted current iu is specified for max. cross-section. | ||
assigned motor power at 200/208 v, 60 hz, 3-phase | 3 hp | ||
rated breaking capacity at 660/690 v (cos phi to iec 60947-3) | 170 a | ||
number of auxiliary contacts (normally closed contacts) | 1 | ||
rated operational current (ie) star-delta at ac-3, 690 v | 25.5 a | ||
rated operational power star-delta at 690 v, 50 hz | 22 kw | ||
lifespan, mechanical | 500,000 operations | ||
control circuit reliability | 1 failure per 100,000 switching operations statistically determined, at 24 v dc, 10 ma) | ||
rated operational voltage (ue) at ac - max | 690 v | ||
10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
number of contacts in series at dc-23a, 120 v | 3 | ||
assigned motor power at 230/240 v, 60 hz, 1-phase | 3 hp | ||
rated operational current (ie) star-delta at ac-3, 220/230 v | 32 a | ||
rated operational current (ie) star-delta at ac-3, 500 v | 32 a |
product length/depth | 179 mm | ||
product width | 65 mm | ||
certifications | ce iec/en 60204 ul 60947-4-1 csa class no.: 3211-05 ul category control no.: nlrv csa iec/en 60947 csa-c22.2 no. 94 vde 0660 iec/en 60947-3 csa file no.: 012528 csa-c22.2 no. 60947-4-1-14 ul ul file no.: e36332 |
||
rated operational current for specified heat dissipation (in) | 32 a | ||
rated operational current (ie) at dc-23a, 24 v | 25 a | ||
10.4 clearances and creepage distances | meets the product standard's requirements. | ||
rated breaking capacity at 220/230 v (cos phi to iec 60947-3) | 260 a | ||
10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
fitted with: | red rotary handle and yellow locking ring | ||
short-circuit current rating (basic rating) | 40a, max. fuse, sccr (ul/csa) 5 ka, sccr (ul/csa) |
||
rated operational current (ie) at dc-23a, 120 v | 12 a | ||
rated conditional short-circuit current (iq) | 1 ka | ||
rated making capacity up to 690 v (cos phi to iec/en 60947-3) | 320 a | ||
assigned motor power at 115/120 v, 60 hz, 1-phase | 1.5 hp | ||
electrical connection type of main circuit | screw connection | ||
number of poles | nine-pole | ||
ambient operating temperature - min | -25 °c | ||
rated uninterrupted current (iu) | 32 a | ||
10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. | ||
product category | main switch | ||
rated operational current (ie) at dc-23a, 48 v | 25 a | ||
number of contacts in series at dc-23a, 24 v | 1 | ||
assigned motor power at 460/480 v, 60 hz, 3-phase | 7.5 hp | ||
rated operational current (ie) at ac-23a, 400 v, 415 v | 32 a | ||
10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
Degree of protection | nema 12 | ||
rated operational current (ie) at ac-23a, 230 v | 32 a | ||
Pollution degree | 3 | ||
rated impulse withstand voltage (uimp) | 6000 v ac | ||
voltage per contact pair in series | 60 v | ||
Tightening torque | 17.7 lb-in, screw terminals 1.6 nm, screw terminals |
||
rated operational current (ie) at ac-3, 660 v, 690 v | 14.7 a | ||
10.2.4 resistance to ultra-violet (uv) radiation | uv resistance only in connection with protective shield. | ||
rated operational current (ie) at ac-3, 380 v, 400 v, 415 v | 23.7 a | ||
number of auxiliary contacts (normally open contacts) | 2 | ||
rated operational power at ac-3, 500 v, 50 hz | 15 kw | ||
assigned motor power at 230/240 v, 60 hz, 3-phase | 3 hp | ||
number of contact units | 6 | ||
rated operational power at ac-23a, 400 v, 50 hz | 15 kw | ||
rated operational current (ie) at dc-23a, 60 v | 25 a | ||
10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
ambient operating temperature (enclosed) - max | 40 °c | ||
rated operational voltage (ue) at ac - min | 690 v | ||
screw size | m4, terminal screw | ||
load rating | 2 x iₑ (with intermittent operation class 12, 25 % duty factor) 1.6 x iₑ (with intermittent operation class 12, 40 % duty factor) 1.3 x iₑ (with intermittent operation class 12, 60 % duty factor) |
||
rated permanent current at ac-21, 400 v | 32 a | ||
climatic proofing | damp heat, constant, to iec 60068-2-78 damp heat, cyclic, to iec 60068-2-30 |
||
rated breaking capacity at 400/415 v (cos phi to iec 60947-3) | 260 a | ||
10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
safe isolation | 440 v ac, between the contacts, according to en 61140 | ||
safety parameter (en iso 13849-1) | b10d values as per en iso 13849-1, table c.1 | ||
rated operational power at ac-23a, 690 v, 50 hz | 15 kw | ||
10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
rated operational power star-delta at 500 v, 50 hz | 18.5 kw | ||
rated operating voltage (ue) - min | 690 v | ||
equipment heat dissipation, current-dependent pvid | 0 w | ||
suitable for | ground mounting intermediate mounting branch circuits, suitable as motor disconnect, (ul/csa) |
||
number of contacts in series at dc-23a, 240 v | 5 | ||
rated operational current (ie) at dc-1, load-break switches l/r = 1 ms | 25 a | ||
10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
number of contacts in series at dc-23a, 60 v | 3 | ||
rated short-time withstand current (icw) | 650 a, contacts, 1 second 0.65 ka |
||
10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
switching capacity (main contacts, general use) | 25 a, rated uninterrupted current max. (ul/csa) | ||
rated operational current (ie) at ac-3, 500 v | 23.7 a | ||
rated operational current (ie) at ac-3, 220 v, 230 v, 240 v | 23.7 a | ||
short-circuit protection rating | 35 a gg/gl, fuse, contacts | ||
switching capacity (auxiliary contacts, pilot duty) | a600 (ul/csa) p600 (ul/csa) |