vickers 125668

DT8P1-10-65-11-IN13

$423,12 1 uds. con envío de 1 a 3 días a United States

Especificaciones

Mounting Position vertical
Ancho 237 mm
Peso 35Kg
product dt8p1 : please refer to product catalog/contact csr for more details
product height 257 mm
Product weight 35 kg
assigned motor current im at 440 - 480 v, 60 hz, 150% overload 77 a
rated operational current for specified heat dissipation (in) 87 a
number of inputs (analog) 2 (parameterizable, 0 - 10 v dc, 0/4 - 20 ma)
rated operational voltage 400 v ac, 3-phase
500 v ac, 3-phase
480 v ac, 3-phase
10.12 electromagnetic compatibility is the panel builder's responsibility. the specifications for the switchgear must be observed.
10.2.3.1 verification of thermal stability of enclosures meets the product standard's requirements.
mains voltage - min 380 v
output frequency - min 0 hz
system configuration type ac supply systems with earthed center point
ambient operating temperature at 150% overload - max 50 °c
ambient operating temperature - max 50 °c
application in industrial area permitted no
climatic proofing < 95 % relative humidity, no condensation, no corrosion, no dripping water
output voltage (u2) 480 v ac, 3-phase
400 v ac, 3-phase
500 v ac, 3-phase
rated operational power at 380/400 v, 50 hz, 110% overload 55 kw
static heat dissipation, non-current-dependent pvs 0 w
10.9.3 impulse withstand voltage is the panel builder's responsibility.
ambient operating temperature - min -10 °c
rated control supply voltage 10 v dc (us, max. 10 ma)
10.5 protection against electric shock does not apply, since the entire switchgear needs to be evaluated.
10.13 mechanical function the device meets the requirements, provided the information in the instruction leaflet (il) is observed.
10.9.4 testing of enclosures made of insulating material is the panel builder's responsibility.
electromagnetic compatibility 1st and 2nd environments (according to en 61800-3)
resolution 0.01 hz (frequency resolution, setpoint value)
assigned motor power at 460/480 v, 60 hz 60 hp
assigned motor power at 460/480 v, 60 hz, 110% overload 75 hp
heat dissipation capacity pdiss 0 w
number of outputs (analog) 1
operating mode sensorless vector control (slv)
u/f control
optional: vector control with feedback (clv)
number of outputs (digital) 1 (parameterizable, 48 v dc/50 ma)
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects meets the product standard's requirements.
10.9.2 power-frequency electric strength is the panel builder's responsibility.
rated operational current (ie) at 110% overload 105 a
ambient storage temperature - max 70 °c
ambient operating temperature at 150% overload - min -10 °c
assigned motor current im at 400 v, 50 hz, 150% overload 81 a
converter type other
10.2.2 corrosion resistance meets the product standard's requirements.
10.2.4 resistance to ultra-violet (uv) radiation meets the product standard's requirements.
altitude above 1000 m with 1 % performance reduction per 100 m
max. 3000 m
max. 1000 m
industrial valves dt8p1-10-65-11-in13
product length/depth 640 mm
product width 237 mm
certifications certified by ul for use in canada
rcm
ce
dnv
iec/en61800-3
ul
ul report applies to both us and canada
csa class no.: 3211-06
specification for general requirements: iec/en 61800-2
csa-c22.2 no. 14
ul 508c
cul
rohs, iso 9001
iec/en 61800-3
safety: en 61800-5-1: 2003
iec/en61800-5
ul category control no.: nmms, nmms2, nmms7. nmms8
ul file no.: e134360
mains voltage - max 500 v
10.11 short-circuit rating is the panel builder's responsibility. the specifications for the switchgear must be observed.
assigned motor current im at 440/480 v, 60 hz, 110% overload 96 a
10.4 clearances and creepage distances meets the product standard's requirements.
10.2.5 lifting does not apply, since the entire switchgear needs to be evaluated.
ambient storage temperature - min -40 °c
fitted with: igbt inverter
radio interference suppression filter
oled display
dc link choke
internal dc link
rated operational power at 380/400 v, 50 hz 45 kw
10.8 connections for external conductors is the panel builder's responsibility.
protection finger and back-of-hand proof, protection against direct contact (bgv a3, vbg4)
number of relay outputs 2 (parameterizable, n/o, 8 a (24 v dc) / 8 a (250 v ac) / 0,4 a (125 v dc))
communication interface lonworks, optional
modbus-tcp, optional
profibus-dp
bacnet/ip, optional
devicenet, optional
canopen®, optional
bacnet ms/tp, optional
ethercat, optional
ethernet ip, optional
modbus-rtu, optional
profinet, optional
output frequency - max 320 hz
switching frequency 3.6 khz, 1 - 10 khz adjustable, fpwm, power section, main circuit
connection to smartwire-dt no
heat dissipation details operation (with 150 % overload)
voltage rating - max 480 vac
number of inputs (digital) 6 (parameterizable, max. 30 v dc)
10.6 incorporation of switching devices and components does not apply, since the entire switchgear needs to be evaluated.
Mounting position vertical
10.2.6 mechanical impact does not apply, since the entire switchgear needs to be evaluated.
10.3 degree of protection of assemblies does not apply, since the entire switchgear needs to be evaluated.
heat dissipation per pole, current-dependent pvid 0 w
product category variable frequency drives
radio interference class c2, c3: depending on the motor cable length, the connected load, and ambient conditions. external radio interference suppression filters (optional) may be necessary.
equipment heat dissipation, current-dependent pvid 1125 w
rated control voltage (uc) 24 v dc (external, max. 250 ma)
suitable for branch circuits, (ul/csa)
rated frequency - min 45 hz
10.2.3.2 verification of resistance of insulating materials to normal heat meets the product standard's requirements.
rated operational current (ie) at 150% overload 87 a
Degree of protection ip21
nema other
rated frequency - max 66 hz
10.7 internal electrical circuits and connections is the panel builder's responsibility.
10.10 temperature rise the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices.
assigned motor current im at 400 v, 50 hz, 110% overload 99 a
frame size fr7
supply frequency 50/60 hz
10.2.7 inscriptions meets the product standard's requirements.
application in domestic and commercial area permitted no
ean 4015081232789
$423,12
Stock 1 uds.
Referencia 125668
Fabricante vickers
Unidades Precio / Unidad
1+ $423,12
  • Registro abierto
    Crea una cuenta en el momento
  • Soporte 24/7
    Pregúntanos a cualquier hora
  • 100% Seguro
    Solo pagos seguros: transferencia bancaria, tarjeta de cédito y PayPal
  • Descuentos por volumen
    Optimice sus suministros