Diagnostic function | Display via LED | ||
Power supply requirements | PELV | ||
Power failure bridging | 10 ms | ||
Current consumption at nominal operating voltage | 40 - 50 mA | ||
Approval | RCM trademark | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
Continuous shock resistance to DIN/IEC 68 Part 2-82 | Tested to severity level 2 | ||
LABS (PWIS) conformity | VDMA24364-B2-L | ||
Relative air humidity | 95 % Non-condensing | ||
Vibration resistance to DIN/IEC 68 Part 2-6 | Tested to severity level 2 | ||
Product weight | 128 g | ||
Electrical connection control interface | Plugs M9 5-pin | ||
Type of mounting | With through-hole |
Mounting position | optional | ||
Nominal operating voltage DC | 24 V | ||
Residual ripple | 4 Vpp | ||
Permissible voltage fluctuations | +/- 25% | ||
KC mark | KC-EMV | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Corrosion resistance class CRC | 1 - Low corrosion stress | ||
Storage temperature | -20 °C ... 70 °C | ||
Degree of protection | IP67 Plug connector in mated condition | ||
Ambient temperature | 0 °C ... 55 °C | ||
Electrical connection measuring system | M12 Socket 5-pin | ||
Control-Interface | Digital CAN bus with Festo protocol Without terminating resistor | ||
Material housing | PBT-reinforced |