Dimensions (W x L x H) | 40 x 91 x 50 mm | ||
Type of mounting | On electrical interface On electrical sub-base | ||
Protocol | CPI-B | ||
Field bus, protocol | CPI-B | ||
Field bus, connection type | Plugs | ||
Field bus, connection pattern | 5 | ||
Field bus interface, transmission rate | 1000 kbit/s | ||
Fieldbus interface 2, connection type | Socket | ||
Fieldbus interface 2, number of pins/wires | 5 | ||
Internal cycle time | 2 ms per 2 byte of user data | ||
Max. address volume, outputs | 4 Byte | ||
Parameterisation | Diagnostic behaviour Fail-safe response | ||
Operator controls | DIL switch | ||
LED display, bus-specific | RUN: Communication OK | ||
Nominal operating voltage DC | 24 V | ||
Max. power supply | 3,4 A | ||
Approval | RCM trademark c UL us listed (OL) | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Degree of protection | IP65 IP67 | ||
Ambient temperature | -5 °C ... 50 °C | ||
Note on materials | Contains paint-wetting impairment substances RoHS-compliant |
Grid dimension | 40 mm | ||
Product weight | 105 g | ||
Fieldbus interface | CP installation system | ||
Fieldbus interface, function | Incoming bus connection Power supply | ||
Field bus, connection system | M9x0.5 | ||
Fieldbus interface, connection pattern | 992.012 | ||
Fieldbus interface 2, function | Outgoing bus connection Power supply | ||
Fieldbus interface 2, connection technology | M9x0.5 | ||
Fieldbus interface 2, connection pattern | 995.398 | ||
Max. address volume, inputs | 4 Byte | ||
Diagnosis | Communication fault System diagnostics Undervoltage | ||
Configuration support | None | ||
LED display, product-specific | PS: Operating voltage for electronics and load supply X1: System status of module at I-Port 1 X2: System status of module at I-Port 2 | ||
Operational voltage range DC | 18 V ... 30 V | ||
Intern power consumption nominal operating voltage | Typ. 50 mA | ||
Power failure bridging | 10 ms | ||
KC mark | KC-EMV | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
Storage temperature | -20 °C ... 70 °C | ||
Note on degree of protection | In assembled state Unused connections sealed | ||
Material housing | PA |