Dimensions (W x L x H) | 40 x 91 x 50 mm | ||
Type of mounting | On electrical interface On electrical sub-base | ||
Protocol | DeviceNet | ||
Field bus, protocol | DeviceNet | ||
Field bus, connection type | Plugs | ||
Field bus, connection pattern | 9 | ||
Note on fieldbus interface | Optional connection technology with accessories: micro style (plug/socket M12x1 A-coded, 5-pin, IP65 protection), open style (terminal strip, 5-pin, IP20 protection) Open style (screw terminal, 5-pin, IP20 protection) Optional connection technology with accessories: | ||
Field bus interface, transmission rate | 125 kbit/s 250 kbit/s 500 kbit/s | ||
Max. address volume, inputs | 8 Byte | ||
Power supply, function | Electronics and load | ||
power supply, connection system | M12x1, B-encoded to EN 61076-2-101 | ||
Power supply, connection pattern | 995.719 | ||
Parameterisation | Diagnostic behaviour Fail-safe and idle response | ||
Configuration support | EDS file | ||
LED display, product-specific | PS: Operating voltage for electronics and load supply X1: System status of module at I-Port 1 X2: System status of module at I-Port 2 | ||
Operational voltage range DC | 18 V ... 30 V | ||
Intern power consumption nominal operating voltage | Typ. 65 mA | ||
Approval | RCM trademark c UL us listed (OL) | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Degree of protection | IP65 IP67 | ||
Ambient temperature | -5 °C ... 50 °C | ||
Note on materials | Contains paint-wetting impairment substances RoHS-compliant |
Grid dimension | 40 mm | ||
Product weight | 90 g | ||
Fieldbus interface | CAN bus | ||
Fieldbus interface, function | Bus connection incoming/outgoing | ||
Field bus, connection system | Sub-D | ||
Fieldbus interface, connection pattern | 995.639 | ||
Field bus interface, electrical isolation | yes | ||
Internal cycle time | 1 ms per 1 byte of user data | ||
Max. address volume, outputs | 8 Byte | ||
Power supply, connection type | Plugs | ||
Power supply, number of pins/wires | 5 | ||
Diagnosis | Communication fault System diagnostics Undervoltage | ||
Additional functions | Acyclic data access via "Explicit Message" QuickConnect System status can be mapped using process data | ||
Operator controls | DIL switch | ||
LED display, bus-specific | IO: I/O status MNS: Network status | ||
Nominal operating voltage DC | 24 V | ||
Max. power supply | 4 A | ||
KC mark | KC-EMV | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
Storage temperature | -20 °C ... 70 °C | ||
Note on degree of protection | In assembled state Unused connections sealed | ||
Material housing | PA PC |