Especificaciones
Series (EMMT) | Servo motor |
---|---|
Motor type (AS) | AC synchronous |
Flange size, motors [mm] (80) | 80 |
Length (S) | Short |
Output shaft | Smooth shaft |
Radial shaft seal | None |
---|---|
Winding (LS) | Low voltage, standard |
Electrical connection (R) | Angled plug, rotatable |
Measuring unit (S) | Absolute encoder, single turn |
Brake (B) | With brake |
Brake current consumption | 0,5 A | ||
Brake coil resistance | 48 Ohm | ||
Brake separation time | ≤ 55 ms | ||
DC brake response delay | ≤ 3 ms | ||
Brake max. friction work | 8.200 J | ||
Switching cycles holding brake | 10 million idle actuations (without friction work!) | ||
Mean time to dangerous failure (MTTFd), subcomponent | 380 years, rotor position sensor | ||
Note on ambient temperature | Up to 80°C with derating of -1.5% per degree Celsius | ||
Note on max. installation height | As of 1,000 m: only with derating of -1.0% per 100 m | ||
Relative air humidity | 0 - 90% | ||
Temperature class as per EN 60034-1 | F | ||
Rating class as per EN 60034-1 | S1 | ||
Motor type to EN 60034-7 | IM B5 IM V1 IM V3 | ||
Degree of protection | IP40 | ||
Concentricity, coaxiality, axial runout to DIN SPEC 42955 | N | ||
Detent torque | <1.0% of the peak torque | ||
Interface code, motor out | 80P | ||
Electrical connection 1, connector system | M23x1 | ||
Electrical connection 1, connection pattern | 995.913 | ||
Note on materials | RoHS-compliant | ||
LABS (PWIS) conformity | VDMA24364 zone III | ||
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
CE mark (see declaration of conformity) | To EU EMC Directive To EU Low Voltage Directive In accordance with EU RoHS Directive | ||
Certificate issuing authority | UL E342973 | ||
Type of winding switch | Star inside | ||
Standstill torque | 1,46 Nm | ||
Peak torque | 2,8 Nm | ||
Max. rotational speed | 6.700 rpm | ||
Nominal power rating of motor | 408 W | ||
Nominal motor current | 2,7 A | ||
Motor constant | 0,48 Nm/A | ||
Voltage constant, phase-to-phase | 34,3 mVmin | ||
Phase-phase winding inductance | 16,3 mH | ||
Winding cross inductivity Lq (phase) | 12,2 mH | ||
Thermal time constant | 42 min | ||
Measuring flange | 250 x 250 x 15 mm, steel | ||
Product weight | 2.720 g | ||
Permissible radial shaft load | 620 N | ||
rotor position sensor, manufacturer designation | ECI 1118 | ||
Rotor position encoder interface | EnDat® 22 | ||
rotor position sensor, DC operating voltage | 5 V | ||
rotor position sensor, position values per revolution | 262,14 | ||
rotor position sensor, system accuracy of angle measurement | -120 arcsec ... 120 arcsec | ||
Operating voltage DC for brake | 24 V |
Power consumption, brake | 12 W | ||
Brake coil inductivity | 1.000 mH | ||
Brake closing time | ≤ 15 ms | ||
Max. brake no-load speed | 10.000 rpm | ||
Mass moment of inertia of brake | 0,249 kgcm² | ||
Mean time to failure (MTTF), subcomponent | 190 years, rotor position sensor | ||
Ambient temperature | -15 °C ... 40 °C | ||
Max. installation height | 4.000 m | ||
Storage temperature | -20 °C ... 70 °C | ||
Conforms to standard | IEC 60034 | ||
Max. winding temperature | 155 °C | ||
Temperature monitoring | Digital motor temperature transmission via EnDat® 2.2 | ||
Mounting position | optional | ||
Note on degree of protection | IP40 for motor shaft without rotary shaft seal IP65 for motor shaft with rotary shaft seal IP67 for motor housing including connection components | ||
Balance quality | G 2.5 | ||
Storage lifetime under nominal conditions | 20.000 h | ||
Electrical connection 1, connection type | Hybrid plug | ||
Electrical connection 1, number of connections/cores | 15 | ||
Pollution degree | 2 | ||
Corrosion resistance class CRC | 0 - No corrosion stress | ||
Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
Approval | RCM trademark c UL us - Recognized (OL) | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK regulations for electrical equipment To UK RoHS instructions | ||
Nominal operating voltage DC | 325 V | ||
Number of pole pairs | 5 | ||
Nominal torque | 1,3 Nm | ||
Nominal rotary speed | 3.000 rpm | ||
Max. mechanical speed | 14.000 rpm | ||
Continuous stall current | 3,1 A | ||
Peak current | 8,4 A | ||
Standstill torque constant | 0,57 Nm/A | ||
Phase-phase winding resistance | 4,93 Ohm | ||
Winding longitudinal inductivity Ld (phase) | 10,2 mH | ||
Electric time constant | 4,9 ms | ||
Thermal resistance | 0,95 K/W | ||
Total mass moment of inertia of output | 0,897 kgcm² | ||
Permissible axial shaft load | 120 N | ||
Rotor position sensor | Absolute single-turn encoder | ||
rotor position sensor, absolute detectable revolutions | 1 | ||
Rotor position sensor, encoder measuring principle | Inductive | ||
rotor position sensor, DC operating voltage range | 3,6 V ... 14 V | ||
Rotor position transducer resolution | 18 bit | ||
Brake holding torque | 4,5 Nm |