model | ex600-spr1a | ||
communication - device type | profibus dp slave | ||
communication - configuration file | gsd file | ||
terminating resistor | internally implemented | ||
output - output type | pnp (negative common) | ||
output - load | solenoid valve with surge voltage suppressor 24 vdc, 1.5 w or less (smc) | ||
output - fail safe | hold/clear/forced power on | ||
enclosure | ip67 (manifold assembly) | ||
Weight | 1.00744 lb |
communication - protocol | profibus dp (dp-v0) | ||
communication - communication speed | 9.6/19.2/45.45/93.75/187.5/500 kbps1.5/3/6/12 mbps | ||
communication - i/o occupation area (inputs/outputs) | max. (512 inputs/512 outputs) | ||
internal current consumption (power supply for control/input) | 80 ma or less | ||
output - number of outputs | 32 outputs (8/16/24/32 outputs selectable) | ||
output - power supply | 24 vdc, 2 a | ||
output - protection | short-circuit protection | ||
Standards | ce marking, ul (csa), rohs recognition |