Stroke | 3 mm ... 2.000 mm | ||
Based on standard | ISO 15552 | ||
Mounting position | optional | ||
Position detection | Via proximity switch Without | ||
Operating pressure | 0,6 bar ... 10 bar | ||
CE mark (see declaration of conformity) | To EU Explosion Protection Directive (ATEX) | ||
Explosion protection | Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX) | ||
ATEX category dust | II 2D | ||
Explosion ignition protection type for dust | Ex h IIIC T120°C Db | ||
Explosion protection certification outside the EU | EPL Db (GB) EPL Gb (GB) | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Ambient temperature | -40 °C ... 120 °C | ||
Theoretical force at 0.6 MPa (6 bar, 87 psi), return stroke | 6.881 N | ||
Type of mounting | Via female thread With accessories | ||
Note on materials | RoHS-compliant | ||
Material cylinder barrel | Wrought aluminium alloy Smooth anodised |
Piston diameter | 125 mm | ||
Cushioning | Elastic cushioning rings/plates at both ends Pneumatic cushioning, adjustable at both ends | ||
Design | Piston Piston rod Profile barrel | ||
Variants | Improved running performance Extended male piston rod thread Piston rod with female thread Custom thread on the piston rod Piston rod with external hexagon Extended piston rod Clamping unit on the piston rod High corrosion protection Dust protection Uniform, slow movement Low friction Through piston rod Through, hollow piston rod Heat-resistant seals max. 120°C Monostable valve, mounted on right, unactuated piston rod, retracted Monostable valve, mounted on right, unactuated piston rod, advanced Bistable valve, mounted on right, unactuated piston rod, retracted Monostable valve, mounted on left, unactuated piston rod, retracted Monostable valve, mounted on left, unactuated piston rod, advanced Bistable valve, mounted on left, unactuated piston rod, retracted Piston rod at one end | ||
Mode of operation | Double-acting | ||
CE marking (see declaration of conformity) | To UK EX instructions | ||
ATEX category gas | II 2G | ||
Explosion ignition protection type for gas | Ex h IIC T4 Gb | ||
Explosion ambient temperature | -20°C <= Ta <= +60°C | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress 3 - high corrosion stress | ||
Impact energy in end positions | 5 J | ||
Theoretical force at 0.6 MPa (6 bar, 87 psi), advance stroke | 6.881 N ... 7.363 N | ||
Pneumatic connection | G1/2 | ||
Material cover | Die-cast aluminium Coated |