Valve function | 3/2-way, closed, monostable | ||
Operating pressure | -13,05 psi ... 116 psi | ||
Type of reset | Mechanical spring | ||
Explosion ignition protection type for gas | Ex ia IIC T6...T5 Ga | ||
Explosion ambient temperature | -55°C <= Ta <= +65°C | ||
Manual override | Detenting | ||
Symbol | 991.308 | ||
Insulation material class | H | ||
Max. input voltage Ui | 31 V | ||
Characteristic coil data | 24 V DC: 1.5 W | ||
Effective internal capacitance Ci | Negligibly low | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Type of mounting | CNOMO |
Type of actuation | Electric | ||
Design | On/off valve | ||
Certificate issuing authority | 21-GA4BO-0070X 21-GA4BO-0071X | ||
Explosion ignition protection type for dust | Ex ia IIIB T135°C Da | ||
Degree of protection | IP65 | ||
Flow direction | Non-reversible | ||
Duty cycle | 100% | ||
Max. input power Pi | -55°C ~+50°C T6 = 2.98W -55°C ~+65°C T5 = 1W -55°C ~+65°C T5 = 2.98W -55°C ~+65°C T6 = 1W | ||
Max. input current Ii | 0,67 A | ||
Effective internal inductivity Li | Negligibly low | ||
Permissible frequency fluctuations | +/- 10% | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Ambient temperature | -20 °C ... 80 °C | ||
Note on materials | Contains paint-wetting impairment substances RoHS-compliant |