Valve function | 2x2/2-way, monostable, closed | ||
Construction width | 20 mm | ||
pneumatic working port | QS-3 | ||
Operating pressure | 0 bar ... 1,5 bar | ||
Degree of protection | IP40 | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Grid dimension | 20 mm | ||
Sealing principle | Soft | ||
Manual override | Non-detenting | ||
Flow direction | Non-reversible | ||
Signal status display | LED | ||
Suitability for vacuum | yes | ||
Max. switching frequency | 10 Hz | ||
Switching time on | 6 ms | ||
Characteristic coil data | 24 V DC: low-current phase 0.7 W, high-current phase 3.0 W | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Media temperature | -5 °C ... 50 °C | ||
Product weight | 30,6 g | ||
Electrical connection | Plug KMH | ||
Pneumatic connection, port 1 | QS-4 | ||
Pneumatic connection, port 2 | QS-3 | ||
Material seals | FPM HNBR NBR | ||
Material screws | Steel |
Type of actuation | Electric | ||
Standard nominal flow rate | 30 l/min | ||
Operating voltage | 24V DC | ||
Type of reset | Mechanical spring | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
Nominal size | 1,5 mm | ||
Exhaust-air function | Without flow control option | ||
Mounting position | optional | ||
Type of piloting | Direct | ||
Symbol | 992.254 | ||
Operating pressure, reversible | -0,95 bar ... 0 bar | ||
Standard flow rate | 30 l/min | ||
Switching time off | 6 ms | ||
Duty cycle | 100% | ||
Permissible voltage fluctuations | +/- 10 % | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
Storage temperature | -20 °C ... 60 °C | ||
Ambient temperature | -5 °C ... 50 °C | ||
Max. cable length | 30 m | ||
Type of mounting | With through-hole | ||
Pneumatic connection, port 11 | QS-4 | ||
Note on materials | RoHS-compliant | ||
Material housing | PA-reinforced PPS reinforced |