Series | MS | ||
Design | Fibre filter | ||
Condensate drain | Fully automatic Manually rotating Semi-automatic | ||
Operating medium | Compressed air to ISO 8573-1:2010 [6:8:4] Inert gases | ||
Bowl guard | Plastic bowl guard Integrated as metal bowl | ||
LABS (PWIS) conformity | VDMA24364-B1/B2-L | ||
Media temperature | -10 °C ... 60 °C | ||
Differential pressure display | Visual display Via pressure sensor | ||
CE mark (see declaration of conformity) | To EU Explosion Protection Directive (ATEX) | ||
ATEX category gas | II 2G | ||
Explosion ignition protection type for gas | Ex h IIC T6 Gb X | ||
Explosion ambient temperature | -10°C <= Ta <= +60°C | ||
Mounting position | Vertical +/-5° | ||
Material filter | Borosilicate fibre | ||
Note on materials | RoHS-compliant |
Size | 6 | ||
Grade of filtration | 0,01 µm ... 1 µm | ||
Operating pressure | 0 bar ... 20 bar | ||
Air purity class at output | Compressed air to ISO 8573-1:2010 [1:7:2] Compressed air to ISO 8573-1:2010 [5:7:3] | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Suitable for use with food | See supplementary material information | ||
Ambient temperature | -10 °C ... 60 °C | ||
Approval | c UL us - Recognized (OL) | ||
Explosion protection | Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX) | ||
ATEX category dust | II 2D | ||
Explosion ignition protection type for dust | Ex h IIIC T60°C Db X | ||
Type of mounting | In-line installation With accessories Either: | ||
Material housing | Die-cast aluminium | ||
Material seals | NBR |