Size | 6 | ||
Mounting position | Horizontal +/-5° | ||
Operating pressure | 3,5 bar ... 10 bar | ||
Approval | RCM trademark | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Storage temperature | -10 °C ... 60 °C | ||
Degree of protection | IP65 With plug socket | ||
Product weight | 3.300 g | ||
Pneumatic connection, port 1 | G1/2 | ||
Material seals | NBR | ||
Material covering | PA-reinforced | ||
Field bus interface | 2x socket, M12x1, 4-pin, D-coded | ||
Operating voltage DC load voltage | 18 V ... 26,4 V | ||
Displayable units | kPa l l/min m3 mbar psi scf scfm | ||
End value for flow rate measuring range | 5.000 l/min | ||
Start value for pressure measuring range | 0 psi | ||
Accuracy in ± % FS | 3 %FS |
Series | MSE | ||
Valve function | 2/2 open, single solenoid | ||
Standard nominal flow rate | 4.500 l/min | ||
KC mark | KC-EMV | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Note on operating and pilot medium | Lubricated operation not possible | ||
LABS (PWIS) conformity | VDMA24364-B1/B2-L | ||
Media temperature | 0 °C ... 50 °C | ||
Ambient temperature | 0 °C ... 50 °C | ||
Electrical connection | 4-pin M18 Plugs | ||
Pneumatic connection, port 2 | G1/2 | ||
Material housing | Die-cast aluminium | ||
Material cover | PA-reinforced | ||
Operating voltage range DC electronics/sensors | 18 V ... 30 V | ||
Reverse polarity protection | For operating voltage connections | ||
Start value for flow rate measuring range | 50 l/min | ||
Accuracy of flow rate | ± (3% o.m.v. + 0.3% FS) | ||
End value for pressure measuring range | 203 psi |