Mounting position | optional | ||
Duty cycle | 100% | ||
Permissible voltage fluctuations | +/- 10 % | ||
Explosion protection certification outside the EU | EPL Dc (CN) EPL Gc (CN) | ||
ATEX category gas | II 3G | ||
Explosion ignition protection type for gas | Ex nA IIC T4 X Gc | ||
Explosion ambient temperature | -5°C <= Ta <= +40°C | ||
Ambient temperature | -5 °C ... 40 °C | ||
Product weight | 55 g | ||
Type of mounting | Via knurled nut | ||
Material solenoid coil | Duroplast Copper Steel |
Min. pick-up time | 10 ms | ||
Characteristic coil data | 24 V DC: 4.5 W | ||
CE mark (see declaration of conformity) | To EU Explosion Protection Directive (ATEX) | ||
Explosion protection | Zone 2 (ATEX) Zone 22 (ATEX) Zone 2 (CN) Zone 22 (CN) | ||
ATEX category dust | II 3D | ||
Explosion ignition protection type for dust | Ex tc IIIC T130°C X Dc IP65 | ||
Degree of protection | IP65 | ||
Max. tightening torque for socket | 0,4 Nm | ||
Electrical connection | 3-pin Plug pins with connection pattern to Festo standard for MSSD-F | ||
Note on materials | RoHS-compliant | ||
Material winding | Copper |