Mounting position | Vertical Horizontal | ||
Symbol | 992.135 | ||
KC mark | KC-EMV | ||
Operating medium | Compressed air to ISO 8573-1:2010 [6:-:4] | ||
Pressure dew point | -40 °C | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Air purity class at output | Compressed air to ISO 8573-1:2010 [2:1:2] at -70°C Compressed air to ISO 8573-1:2010 [2:2:2] at -40°C | ||
Ambient temperature | 5 °C ... 50 °C | ||
Type of mounting | With accessories | ||
Pneumatic connection, port 2 | G3/8 | ||
Material housing | Wrought aluminium alloy |
Design | Cold regenerating adsorption dryer | ||
Inlet pressure 1 | 4 bar ... 16 bar | ||
CE mark (see declaration of conformity) | In accordance with EU Pressure Equipment Directive To EU EMC Directive To EU Low Voltage Directive | ||
Note on operating and pilot medium | Lubricated operation not possible No water in liquid form | ||
Pressure dewpoint with reduced cross-section | -70 °C | ||
Storage temperature | -20 °C ... 60 °C | ||
Media temperature | 2 °C ... 50 °C | ||
Product weight | 16.500 g | ||
Pneumatic connection, port 1 | G3/8 | ||
Note on materials | RoHS-compliant |