activation | electrically | ||
switching principle | 3/2, with spring return | ||
Manual override | without detent | ||
compressed air connection | base plate | ||
working pressure min. | 0 bar | ||
operational↩voltage | 24 v dc | ||
electrical connection size | m12 | ||
power consumption dc | 1.5 w | ||
min. ambient temperature | -10 °c | ||
Weight | 0.035 kg |
frame size | do16 | ||
Valve function | nc | ||
nominal flow qn | 18 l/min | ||
compressed air connection output | base plate | ||
working pressure max | 10 bar | ||
voltage tolerance dc | -10% / +10% | ||
Sealing principle | soft seal | ||
Duty cycle | 100 % | ||
max. ambient temperature | 50 °c | ||
Housing Material | polyphenylene sulfide, polyamide fiber-glass reinforced |