Festo 563795 Sensor de caudal

SFAB-1000U-HQ12-2SA-M12

$957,35 1 uds. con envío de 1 a 3 días a United States

Especificaciones

Series (SFAB) Flow sensor
Flow measuring range (1000) Max. 1000 l/min
Flow rate input (U) Unidirectional
Type of mounting (H) H-rail mounting
Pneumatic connection (Q12) Push-in connector 12 mm
Electrical output 1 (2SA) 2x PNP or NPN, 1 analogue output 4 ... 20 mA
Electrical output 2 None
Electrical connection (M12) Plug M12, A-coded
Connecting cable, straight socket None
Connecting cable, angled plug socket None
EU certification None
Electrical accessories None
Certificate None
Ambient temperature 0 °C ... 50 °C
Approval RCM trademark c UL us - Recognized (OL)
CE marking (see declaration of conformity) To UK instructions for EMC To UK RoHS instructions
ATEX category gas II 3G
ATEX category dust II 3D
Explosion ambient temperature 0°C <= Ta <= +50°C
Note on materials RoHS-compliant
Flow direction Unidirectional P1 -> P2
Measurement method Heat Loss
End value for flow rate measuring range 3 l/min ... 1.000 l/min
Temperature measurement end value 50 °C
Operating medium Compressed air to ISO 8573-1:2010 [6:4:4] Compressed air to ISO 8573-1:2010 [7:4:4] Nitrogen
Nominal temperature 23 °C
Repetition accuracy offset in ± %FS 0,2 %FS
Temperature coefficient span in ± %FS/K Typ. 0.1%FS/K
Switching output 2 x PNP or 2 x NPN, switchable
Switching element function N/C or N/O contact, switchable
Analogue output 0 - 10 V 4 - 20 mA 1 - 5 V
Flow characteristic curve end value 10 l/min ... 1.000 l/min
Temperature characteristic curve end value 100 °C
Output characteristic curve starting value 4 mA
Max. load resistance current output 500 Ohm
Short circuit current rating yes
Protocol IO-Link®
IO-Link®, device profile Function extended identification Function measurement data, standard resolution Function multiple switching signal Firmware update Function locator Function Teach single value Function Teach two values Identification and diagnostics Smart sensor - SSP 4.1.2
IO-Link, SIO-Mode support Yes
IO-Link®, process data length output 0 bit
IO-Link, Process data content IN Flow rate measured value 16-bit MDC Flow rate monitoring 2-bit SSC Temperature measured value 16 bit MDC Temperature monitoring 2-bit SSC Volume / mass pulse 1 bit SSC
IO-Link®, minimum cycle time 1,2 ms
Operational voltage range DC 15 V ... 30 V
Reverse polarity protection For all electrical connections
Electrical connection 1, connector system M12x1, A-coded to EN 61076-2-101
Electrical connection 1, connection pattern 00995383
Mounting position optional
Product weight 160 g
Display type Illuminated LCD, multi-colour
Setting options IO-Link® Teach-in Via display and keys
Degree of protection IP65
Protection class III
LABS (PWIS) conformity VDMA24364-B1/B2-L
Symbol 00992242 00992243 00995566
CE mark (see declaration of conformity) To EU EMC Directive To EU Explosion Protection Directive (ATEX) In accordance with EU RoHS Directive
Explosion protection Zone 2 (ATEX) Zone 22 (ATEX)
Explosion ignition protection type for gas Ex nA IIC T5 X Gc
Explosion ignition protection type for dust Ex tc IIIB T80°C X Dc IP54
Certificate issuing authority UL E322346
Measured variable Mass flow rate Temperature Volume Volumetric flow rate
Measuring principle Thermal
Start value for flow rate measuring range 0,1 l/min ... 10 l/min
Temperature measurement start value 0 °C
Operating pressure 0 MPa ... 1 MPa
Media temperature 0 °C ... 50 °C
Accuracy of flow rate ± (3% o.m.v. + 0.3% FS)
Repetition accuracy span in ± %FS 0,8 %FS
Pressure influence span in ± %FS/bar 0,5 %FS/b.
Switching function Window comparator Threshold value comparator
Max. output current 100 mA
Flow characteristic curve start value 0 l/min
Temperature characteristic curve start value 0 °C
Output characteristic curve start value 0 V
Output characteristic curve end value 20 mA
Min. load resistance voltage output 10 kOhm
Overload protection Available
IO-Link®, revision ID V1.1
IO-Link®, transmission rate COM3
IO-Link®, port type Class A
IO-Link®, process data length input 64 bit
IO-Link, Service data IN Volume / mass measured value 32 bit MDC
IO-Link, Data storage required 500 Byte
No-load supply current 90 mA ... 120 mA
Electrical connection 1, connection type Plugs
Electrical connection 1, number of connections/cores 5
Type of mounting With through-hole With H-rail Via wall/surface bracket
Pneumatic connection For tubing O.D. 6 mm For tubing O.D. 8 mm For tubing outside diameter of 10 mm For tubing O.D. 12 mm For tubing outside Ø 1/4" For tubing outside Ø 5/16" For tubing outside Ø 3/8"
Material housing PA-reinforced
Displayable units g g/min l l/h l/min m3 m3/h scf scfm
Protection against tampering IO-Link PIN code
Pressure drop < 100 mbar
Corrosion resistance class CRC 2 - Moderate corrosion stress
$957,35
Stock 1 uds.
Referencia 563795
Fabricante Festo
Unidades Precio / Unidad
1+ $957,35

  • Registro abierto
    Crea una cuenta en el momento
  • Soporte 24/7
    Pregúntanos a cualquier hora
  • 100% Seguro
    Solo pagos seguros: transferencia bancaria, tarjeta de cédito y PayPal
  • Descuentos por volumen
    Optimice sus suministros