Design | For T-slot | ||
Symbol | 991.153 | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
Special characteristics | Welding field resistant Resistant to welding spatter | ||
Instructions on use | Support / actuator-sensor overview "The right sensor for the actuator" | ||
Measuring principle | Magneto-inductive | ||
Repetition accuracy | 0,2 mm | ||
Switching behavior during welding process | Output signal freezes | ||
Switch-on time | 38 ms | ||
Max. switching frequency | 14 Hz | ||
Max. switching capacity DC | 6 W | ||
Off-state current | ≤ 0,01 mA | ||
Overload protection | Available | ||
Residual ripple | 10 % | ||
Electrical connection 1, connection type | Plugs | ||
Electrical connection 1, number of connections/cores | 3 | ||
Electrical connection 1, connection pattern | 995.573 | ||
Material electrical contact | Gold-plated brass | ||
Mounting position | optional | ||
Housing colour | Black | ||
Switching status indication | Yellow LED | ||
Immunity to magnetic fields | 45 - 65 Hz Alternating magnetic field |
Based on standard | EN 60947-5-2 | ||
Approval | RCM trademark | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Note on materials | RoHS-compliant | ||
Measured variable | Position | ||
Ambient temperature | -25 °C ... 70 °C | ||
Switching output | PNP | ||
Switching element function | N/O contact | ||
Switch-off time | 20 ms | ||
Max. output current | 200 mA | ||
Voltage drop | ≤ 3 V | ||
Short circuit current rating | Pulsed | ||
Operational voltage range DC | 10 V ... 30 V | ||
Reverse polarity protection | For all electrical connections | ||
Electrical connection 1, connector system | M12x1, A-coded to EN 61076-2-101 | ||
Electrical connection 1, type of mounting | Screw-type lock | ||
Connection outlet orientation | Lateral | ||
Type of mounting | Clamped in T-slot Insertable in the slot from above | ||
Product weight | 19 g | ||
Material housing | Wrought aluminium alloy PA TPE-U(PU) High-alloy stainless steel | ||
Degree of protection | IP65 IP67 | ||
LABS (PWIS) conformity | VDMA24364-B2-L |