Festo 8001200 Sensor de presión

SPAU-P1R-T-G18M-LK-V-M12D

$235,86 1 uds. con envío de 1 a 3 días a United States

Especificaciones

Series (SPAU) Pressure sensor
Pressure measuring range (P1) 0 ... 1 bar
Pressure inlet (R) Relative pressure
Type of mounting (T) Threaded mounting
Pneumatic connection (G18) G1/8
Thread type (M) Male
Outlet orientation Rear
Display None
Electrical output 1 (LK) IO-Link®
Electrical output 2 (V) 0 ... 10 V
Electrical connection (M12) Plug M12, A-coded
Electrical outlet direction (D) Underneath
Electrical accessories None
Protective devices None
Certifi cate None
Approval RCM trademark c UL us listed (OL)
CE marking (see declaration of conformity) To UK instructions for EMC To UK RoHS instructions
Note on materials RoHS-compliant
Measurement method Piezoresistive pressure sensor
End value for pressure measuring range 16 bar
Note on operating and pilot medium Lubricated operation possible
Ambient temperature 0 °C ... 50 °C
Repetition accuracy in ± %FS 0,3 %FS
Switching function Freely programmable
Max. output current 100 mA
Rise time 3 ms
Protocol IO-Link®
IO-Link, Profile Smart sensor profile
IO-Link, communication mode COM2 (38.4 kBaud)
IO-Link, Port class A
IO-Link, Process data length IN 2 bytes
IO-Link, Min. cycle time 3 ms
Operational voltage range DC 20 V ... 30 V
Electrical connection 1, connection type Plugs
Mounting position optional
Display type Illuminated LCD LED
Setting range threshold value 0 % ... 100 %
Degree of protection IP65 IP67
LABS (PWIS) conformity VDMA24364-B1/B2-L
CE mark (see declaration of conformity) To EU EMC Directive In accordance with EU RoHS Directive
KC mark KC-EMV
Measured variable Relative pressure
Start value for pressure measuring range -1 bar
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4] Inert gases
Media temperature 0 °C ... 50 °C
Resolution ADC 12 bit
Temperature coefficient in ± %FS/K 0,05 %FS/K
Switching element function N/C or N/O contact, switchable
Analogue output 0 - 10 V 4 - 20 mA 1 - 5 V
Short circuit current rating yes
IO-Link, Protocol version Device V 1.1
IO-Link, Function classes Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel
IO-Link, SIO-Mode support Yes
IO-Link, Process data length OUT 0 bytes
IO-Link, Process data content IN 14 bit PDV (pressure measurement value) 2 bit BDC (pressure monitoring)
IO-Link, Data storage required 500 Byte
Reverse polarity protection For all electrical connections
Electrical connection 1, connector system M12x1, A-coded to EN 61076-2-101 M8x1, A-coded, to EN 61076-2-104
Pneumatic connection M5 M7 G1/8 R1/8 R1/4 1/8 NPT QS-4 QS-6 QS-5/32
Displayable units MPa bar inH2O inHg kPa kgf/cm² mmHg psi
Setting range hysteresis 0 % ... 90 %
Corrosion resistance class CRC 2 - Moderate corrosion stress
$235,86
Stock 1 uds.
Referencia 8001200
Fabricante Festo
Unidades Precio / Unidad
1+ $235,86

  • Registro abierto
    Crea una cuenta en el momento
  • Soporte 24/7
    Pregúntanos a cualquier hora
  • 100% Seguro
    Solo pagos seguros: transferencia bancaria, tarjeta de cédito y PayPal
  • Descuentos por volumen
    Optimice sus suministros