Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
Valve terminal interface | Type 44, VTSA-F-CB | ||
Max. number of valve positions | 12 with bistable valves 24 with monostable valves | ||
Parameterisation | Fail-safe per channel Forcing per channel Idle mode per channel Module monitoring | ||
Operational voltage range DC | 21,6 V ... 26,4 V | ||
Max. power supply per channel | 0.2 A | ||
Nominal operating voltage DC | 24 V | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
Storage temperature | -20 °C ... 60 °C | ||
Ambient temperature | -5 °C ... 50 °C | ||
Electrical control | Fieldbus | ||
Note on materials | RoHS-compliant | ||
Material cover | PA | ||
Material screws | Steel |
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
Diagnosis | Wire break per solenoid coil Short circuit of valves Undervoltage of valves | ||
LED display | 1 Group diagnostics | ||
Fuse protection (short circuit) | Internal electronic fuse protection per valve output | ||
Intern power consumption nominal operating voltage | Typ. 110 mA for electronics with CPX-FVDA-P2 Typ. 25 mA for pneumatic valves without CPX-FVDA-P2 Typ. 45 mA for electronics without CPX-FVDA-P2 Typ. 90 mA for valves with CPX-FVDA-P2 | ||
Max. total current per module | 4,5 A | ||
Isolation channel - internal bus | Yes, when using an additional power supply for the valves | ||
Corrosion resistance class CRC | 0 - No corrosion stress | ||
Degree of protection | IP65 | ||
Product weight | 734 g | ||
Electrical connection | Via CPX | ||
Material sub-base | Die-cast aluminium | ||
Material seals | NBR |