Product weight | 194 g | ||
Material housing | Painted die cast aluminium PA-reinforced | ||
Position of connection | Top | ||
Diagnostics via LED | Diagnostics per module Load power supply | ||
Max. number of valve positions | 32 | ||
Max. number of valve coils | 32 | ||
Fuse protection (short circuit) | Internal electronic fuse per channel | ||
Intrinsic current consumption at nominal operating voltage load | Typically 15 mA | ||
Nominal DC operating voltage, electronics/sensors | 24 V | ||
Power failure bridging | 10 ms | ||
Permissible voltage fluctuations for electronics/sensors | ± 25% | ||
Power supply, function | Incoming electronics/sensors and load | ||
power supply, connection system | M8x1, A-coded to EN 61076-2-104 | ||
Power transmission, function | Outgoing electronics/sensors and load | ||
Power transmission, connection technology | M8x1, A-coded to EN 61076-2-104 | ||
Approval | RCM trademark | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
Corrosion resistance class CRC | 3 - high corrosion stress | ||
Storage temperature | -40 °C ... 70 °C | ||
Protection against direct and indirect contact | PELV SELV | ||
Note on degree of protection | In assembled state Unused connections sealed | ||
Nominal altitude of use | <= 2000 m NHN | ||
Max. cable length | 50 m system communication | ||
Communication interface, connection type | 2x socket | ||
Communication interface, number of pins/wires | 4 | ||
Communication interface, shielding | yes |
Note on materials | RoHS-compliant | ||
Material threaded sleeve | Nickel-plated brass | ||
Reverse polarity protection | yes | ||
Diagnostics per internal communication | Electronics/sensors overvoltage Electronics/sensors undervoltage | ||
Valve terminal structure | Valve sizes can be mixed | ||
Dimensions (W x L x H) | 43.1 mm x 107.5 mm x 50.2 mm | ||
Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 30 mA | ||
Max. power supply | 2 x 4 A (external fuse required) | ||
Nominal operating voltage DC of load | 24 V | ||
Electrical isolation of outputs between channel - internal communication | yes | ||
Permissible voltage fluctuation of load | ± 10% | ||
Power supply, connection type | Plugs | ||
Power supply, number of pins/wires | 4 | ||
Power transmission, connection type | Socket | ||
Power transmission, number of pins/wires | 4 | ||
KC mark | KC-EMV | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
LABS (PWIS) conformity | VDMA24364-B1/B2-L | ||
Relative air humidity | 5 - 95% Non-condensing | ||
Degree of protection | IP65 IP67 | ||
Ambient temperature | -5 °C ... 50 °C | ||
Max. tightening torque | 1,7 Nm | ||
Communication interface, function | System communication XF10 IN / XF20 OUT | ||
Communication interface, connection technology | M8x1, D-coded according to EN 61076-2-114 | ||
Communication interface, protocol | AP-COM | ||
Type of mounting | Tie rod |
Stock | 21 uds. |
---|---|
Referencia | 8087171 |
Fabricante | Festo |
Unidades | Precio / Unidad |
---|---|
1 - 4 | $396,76 |
5 - 9 | $388,82 |
10 - 14 | $380,88 |
15+ | $372,95 |