Especificaciones
Series (VSVA) | Standards-based valve to ISO 5599-1 |
---|---|
Directional control valve type (B) | Sub-base valve |
Valve function (B52) | 5/2-way valve, double solenoid/bistable |
Reset method for monostable/single solenoid valves | None |
Pilot air | Internal |
Manual override (H) | Non-detenting |
---|---|
Pneumatic connection (A2) | 18 mm (02) ISO 15407-1/-2 |
Nominal operating voltage (1) | 24 V DC |
Electrical connection (R2) | Central connector M8 |
Display (L) | LED |
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
Media temperature | -5 °C ... 50 °C | ||
Ambient temperature | -5 °C ... 50 °C | ||
Product weight | 140 g | ||
Type of mounting | On sub-base | ||
Valve function | 5/2 double solenoid | ||
Construction width | 18 mm | ||
pneumatic working port | Sub-base size 18 mm to ISO 15407-1 Sub-base size 02 to VDMA 24563 | ||
Operating pressure | 3 bar ... 8 bar | ||
Approval | C-Tick c UL us - Recognized (OL) | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Nominal size | 5 mm | ||
Sealing principle | Soft | ||
Conforms to standard | ISO 15407-1 VDMA 24563 | ||
Type of piloting | Pilot actuated | ||
Flow direction | Non-reversible | ||
lap | Positive overlap | ||
Flow rate of valve | 750 l/min | ||
Flow rate of pneumatically interlinked valve | 550 l/min | ||
Operational voltage range DC | 21,6 V ... 26,4 V | ||
Max. positive test pulse with 0 signal | 500 µs | ||
Characteristic coil data | 24 V DC: low-current phase 1.0 W, high-current phase 2.4 W |
Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Relative air humidity | 0 - 90% | ||
Max. tightening torque for valve mounting | 0,9 Nm ... 1,1 Nm | ||
Electrical connection | 4-pin M8x1 Central plug Round design | ||
Note on materials | RoHS-compliant | ||
Type of actuation | Electric | ||
Standard nominal flow rate | 550 l/min | ||
Operating voltage | 24V DC | ||
Design | Piston gate valve | ||
CE mark (see declaration of conformity) | To EU EMC Directive | ||
Degree of protection | IP65 | ||
Exhaust-air function | With flow control option | ||
Mounting position | optional | ||
Manual override | Non-detenting | ||
Pilot air supply | Internal | ||
Symbol | 991.005 | ||
Signal status display | LED | ||
Flow rate of valve on individual sub-base | 550 l/min | ||
Switching time reversal | 10 ms | ||
Duty cycle | 100% | ||
Max. negative test pulse with 1 signal | 500 µs | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |