Valve function | 5/2-way, monostable | ||
Construction width | 18 mm | ||
pneumatic working port | Sub-base size 18 mm to ISO 15407-2 G1/8 | ||
Design | Piston gate valve | ||
KC mark | KC-EMV | ||
Degree of protection | IP65 NEMA 4 | ||
Exhaust-air function | With flow control option Via throttle plate Via individual sub-base | ||
Mounting position | optional | ||
Type of piloting | Pilot actuated | ||
Flow direction | Non-reversible | ||
Measuring principle | Inductive | ||
Reverse polarity protection sensor | For all electrical connections | ||
Switching position sensing | Normal position via sensor | ||
Pilot pressure | 3 bar ... 10 bar | ||
Flow rate of valve on individual sub-base | 600 l/min | ||
Flow rate of pneumatically interlinked valve | 550 l/min | ||
Switching time on | 12 ms | ||
Valve - sensor switching time off | 9 ms | ||
Max. positive test pulse with 0 signal | 1.500 µs | ||
Nominal operating voltage DC | 24 V | ||
Characteristic coil data | 24 V DC: 1.6 W | ||
Pollution degree | 3 | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
Corrosion resistance class CRC | 0 - No corrosion stress | ||
Relative air humidity | 0 - 90% | ||
Ambient temperature | -5 °C ... 50 °C | ||
Product weight | 140 g | ||
Short-circuit strength sensor | Pulsed | ||
Max. output current sensor | 200 mA | ||
Residual ripple sensor | ± 10% | ||
Electrical connection | 4-pin Plugs To ISO 15407-2 | ||
Type of mounting | On sub-base | ||
Pilot exhaust port 82/84 | Ducted Not ducted Either: | ||
Pneumatic connection, port 2 | Sub-base size 18 mm to ISO 15407-2 | ||
Pneumatic connection, port 4 | Sub-base size 18 mm to ISO 15407-2 | ||
Note on materials | RoHS-compliant | ||
Material housing | Die-cast aluminium PA | ||
Switching element function | N/C contact |
Type of actuation | Electric | ||
Standard nominal flow rate | 550 l/min | ||
Operating pressure | -0,9 bar ... 10 bar | ||
Type of reset | Mechanical spring | ||
CE mark (see declaration of conformity) | To EU EMC Directive | ||
Nominal size | 5 mm | ||
Sealing principle | Soft | ||
Manual override | Detenting via accessory Non-detenting | ||
Pilot air supply | External | ||
Symbol | 997.392 | ||
lap | Positive overlap | ||
Signal status display | LED | ||
Switching status display sensor | LED | ||
Flow rate of valve | 750 l/min | ||
Valve flow rate, pneumatically linked, flow optimized | 700 l/min | ||
Switching time off | 38 ms | ||
Valve - sensor switching time on | 32 ms | ||
Duty cycle | 100% | ||
Max. negative test pulse with 1 signal | 800 µs | ||
Switching output | PNP | ||
Immunity to surge | 2,5 kV | ||
Permissible voltage fluctuations | +/- 10 % | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
Media temperature | -5 °C ... 50 °C | ||
Sound pressure level | 85 dB(A) | ||
Max. tightening torque for valve mounting | 0,8 Nm ... 1,2 Nm | ||
Operating voltage range, DC sensor | 10 V ... 30 V | ||
Idle current sensor | ≤ 10 mA | ||
Max. switching frequency sensor | 5.000 Hz | ||
Voltage drop sensor | ≤ 2 V | ||
Sensor connection | Plug 3-pin M8x1 | ||
Pilot air port 12/14 | Sub-base size 18 mm to ISO 15407-2 | ||
Pneumatic connection, port 1 | Sub-base size 18 mm to ISO 15407-2 | ||
Pneumatic connection, port 3 | Sub-base size 18 mm to ISO 15407-2 | ||
Pneumatic connection, port 5 | Sub-base size 18 mm to ISO 15407-2 | ||
Material seals | FPM NBR | ||
Material screws | Galvanised steel |