Valve function | 5/3 exhausted | ||
Construction width | 52 mm | ||
pneumatic working port | Sub-base size 2 to ISO 5599-2 G1/2 | ||
Operating pressure | -0,9 bar ... 10 bar | ||
Approval | c UL us - Recognized (OL) | ||
CE mark (see declaration of conformity) | To EU EMC Directive | ||
Grid dimension | 59 mm | ||
Sealing principle | Soft | ||
Conforms to standard | ISO 5599-2 | ||
Type of piloting | Pilot actuated | ||
Flow direction | optional | ||
Signal status display | LED | ||
Flow rate of valve | 3.600 l/min | ||
Flow rate of pneumatically interlinked valve | 2.800 l/min | ||
Switching time on | 23 ms | ||
Max. positive test pulse with 0 signal | 1.000 µs | ||
Nominal pick-up current per solenoid coil | 165 mA up to 30 ms | ||
Characteristic coil data | 24 V DC: 4.6 W | ||
Pollution degree | 3 | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
Corrosion resistance class CRC | 0 - No corrosion stress | ||
Relative air humidity | 0 - 90% | ||
Product weight | 780 g | ||
Type of mounting | On sub-base | ||
Pilot exhaust port 82/84 | Ducted Not ducted as per standard Either: | ||
Pneumatic connection, port 2 | Sub-base size 2 to ISO 5599-2 | ||
Pneumatic connection, port 4 | Sub-base size 2 to ISO 5599-2 | ||
Note on materials | RoHS-compliant | ||
Material housing | Die-cast aluminium PA |
Type of actuation | Electric | ||
Standard nominal flow rate | 2.800 l/min | ||
Operating voltage | 24V DC | ||
Design | Piston gate valve | ||
KC mark | KC-EMV | ||
Degree of protection | IP65 NEMA 4 | ||
Exhaust-air function | With flow control option Via throttle plate Via individual sub-base | ||
Mounting position | optional | ||
Manual override | Detenting via accessory Non-detenting | ||
Pilot air supply | External | ||
Symbol | 992.939 | ||
Pilot pressure | 3 bar ... 10 bar | ||
Flow rate of valve on individual sub-base | 3.200 l/min | ||
Switching time off | 60 ms | ||
Duty cycle | 100% | ||
Max. negative test pulse with 1 signal | 3.500 µs | ||
Nominal current with current reduction | 35 mA after 30 ms | ||
Immunity to surge | 2,5 kV | ||
Permissible voltage fluctuations | +/- 10 % | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
Media temperature | -5 °C ... 50 °C | ||
Ambient temperature | -5 °C ... 50 °C | ||
Electrical connection | Plug-in To ISO 5599-2 | ||
Pilot air port 12/14 | Sub-base size 2 to ISO 5599-2 | ||
Pneumatic connection, port 1 | Sub-base size 2 to ISO 5599-2 | ||
Pneumatic connection, port 3 | Sub-base size 2 to ISO 5599-2 | ||
Pneumatic connection, port 5 | Sub-base size 2 to ISO 5599-2 | ||
Material seals | FPM HNBR NBR | ||
Material screws | Galvanised steel |
Stock | Pedir cotización |
---|---|
Referencia | 8034959 |
Fabricante | FESTO |
Unidades | Precio / Unidad |
---|---|
1+ | $240,84 |