Festo 574347 Electroválvula

VUVG-B10A-M52-MZT-F-1P3

$73,07 3 uds. con envío de 1 a 3 días a United States

Especificaciones

Series (VUVG) Solenoid valve
Directional control valve type (B) Sub-base valve
Design principle Piston spool
Size (10A) Size 10, deviating fl ow
Pilot air Internal
Valve function (M52) 5/2-way valve, single solenoid/monostable
Reset method for monostable/single solenoid valves (M) Mechanical spring
Pilot air (Z) External
Manual override (T) Non-detenting, detenting with accessories
Pneumatic connection (F) Flange/sub-base
Exhaust No fi tting
Nominal operating voltage (1) 24 V DC
Electrical connection (P3) Without electrical sub-base
Circuitry None
Mounting position optional
Media temperature -5 °C ... 60 °C
Ambient temperature -5 °C ... 60 °C
Electrical connection Via electrical sub-base
Note on materials RoHS-compliant
Material housing Wrought aluminium alloy
Type of actuation Electric
Standard nominal flow rate 80 l/min
Operating voltage 24V DC
Design Piston gate valve
Approval RCM trademark c UL us - Recognized (OL)
Nominal size 1,4 mm
Sealing principle Soft
Type of piloting Pilot actuated
Symbol 991.025
Pilot pressure 3 bar ... 8 bar
Switching time off 21 ms
Duty cycle 100%
Max. negative test pulse with 1 signal 900 µs
Permissible voltage fluctuations +/- 10 %
Note on operating and pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Restrictions for environmental and media temperature -5 ... 50° C Without holding current reduction
Corrosion resistance class CRC 2 - Moderate corrosion stress
LABS (PWIS) conformity VDMA24364-B1/B2-L
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Product weight 37 g
Type of mounting On manifold rail
Material seals HNBR NBR
Valve function 5/2-way, monostable
Valve size 10 mm
pneumatic working port Flange
Operating pressure -0,9 bar ... 8 bar
Type of reset Mechanical spring
Degree of protection IP40 IP65 With plug socket
Exhaust-air function With flow control option
Manual override Detenting Non-detenting Covered
Pilot air supply External
lap Positive overlap
Suitability for vacuum yes
Switching time on 7 ms
Max. positive test pulse with 0 signal 700 µs
Characteristic coil data 24 V DC: 1.0 W 24 V DC: low-current phase 0.3 W, high-current phase 1.0 W
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Vibration resistance Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
$73,07
Stock 3 uds.
Referencia 574347
Fabricante Festo
Unidades Precio / Unidad
1+ $73,07

  • Registro abierto
    Crea una cuenta en el momento
  • Soporte 24/7
    Pregúntanos a cualquier hora
  • 100% Seguro
    Solo pagos seguros: transferencia bancaria, tarjeta de cédito y PayPal
  • Descuentos por volumen
    Optimice sus suministros