Especificaciones
Series (VUVG) | Solenoid valve |
---|---|
Directional control valve type (L) | In-line valve |
Design principle | Piston spool |
Size (10) | Size 10 |
Pilot air | Internal |
Valve function (T32H) | 2x3/2-way valve, 1x normally closed, 1x normally open |
Reset method for monostable/single solenoid valves (A) | Pneumatic spring |
Pilot air | Internal |
---|---|
Manual override (T) | Non-detenting, detenting with accessories |
Pneumatic connection (M5) | M5 |
Exhaust | No fi tting |
Nominal operating voltage (1) | 24 V DC |
Electrical connection | None |
Circuitry (R) | Holding current reduction with integrated protective circuit |
Exhaust-air function | With flow control option | ||
Ambient temperature | -5 °C ... 60 °C | ||
Electrical connection | Via electrical sub-base | ||
Pneumatic connection, port 1 | M5 | ||
Pneumatic connection, port 3 | M5 | ||
Pneumatic connection, port 5 | M5 | ||
Material seals | HNBR NBR | ||
Valve function | 2x3/2-way, open/closed, monostable | ||
Valve size | 10 mm | ||
pneumatic working port | M5 | ||
Operating pressure | 1,5 bar ... 8 bar | ||
Type of reset | Pneumatic spring | ||
Degree of protection | IP65 With plug socket | ||
Sealing principle | Soft | ||
Manual override | Detenting Non-detenting Covered | ||
Pilot air supply | Internal | ||
lap | Positive overlap | ||
Suitability for vacuum | no | ||
Switching time on | 6 ms | ||
Max. positive test pulse with 0 signal | 700 µs | ||
Characteristic coil data | 24 V DC: 1.0 W | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
LABS (PWIS) conformity | VDMA24364-B1/B2-L |
Media temperature | -5 °C ... 60 °C | ||
Product weight | 55 g | ||
Type of mounting | On manifold rail With through-hole Either: | ||
Pneumatic connection, port 2 | M5 | ||
Pneumatic connection, port 4 | M5 | ||
Note on materials | RoHS-compliant | ||
Material housing | Wrought aluminium alloy | ||
Type of actuation | Electric | ||
Standard nominal flow rate | 150 l/min | ||
Operating voltage | 24V DC | ||
Design | Piston gate valve | ||
Approval | RCM trademark c UL us - Recognized (OL) | ||
Nominal size | 2,7 mm | ||
Mounting position | optional | ||
Type of piloting | Pilot actuated | ||
Symbol | 992.898 | ||
Pilot pressure | 1,5 bar ... 8 bar | ||
Switching time off | 15 ms | ||
Duty cycle | 100% | ||
Max. negative test pulse with 1 signal | 900 µs | ||
Permissible voltage fluctuations | +/- 10 % | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Restrictions for environmental and media temperature | -5 ... 50° C Without holding current reduction | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress |